Communications - Scientific Letters of the University of Zilina 2013, 15(11):102-106 | DOI: 10.26552/com.C.2013.2A.102-106

Influence of Selected Parameters on Eddy Currents Attenuation in Non-Destructive Inspection

Ladislav Janousek1
1 Department of Electromagnetic and Biomedical Engineering, Faculty of Electrical Engineering, University of Zilina, Zilina, Slovak Republic

Eddy currents attenuation in conductive materials under non-destructive inspection is analyzed in the paper. Influence of selected parameters of the inspection on the attenuation is studied by numerical means. A circular driving coil is employed to induce eddy currents in conductive plates under harmonic excitation. Outer diameter of the coil is varied together with the clearance between the coil and a plate surface for two plates with different thickness. Attenuation of the eddy current density in plates is studied and the results are analyzed in absolute values and the normalized ones as well. It is demonstrated that the investigated parameters of the inspection have significant impact on the attenuation.

Keywords: non-destructive evaluation, eddy currents, attenuation, penetration depth

Published: July 31, 2013  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Janousek, L. (2013). Influence of Selected Parameters on Eddy Currents Attenuation in Non-Destructive Inspection. Communications - Scientific Letters of the University of Zilina15(2A), 102-106. doi: 10.26552/com.C.2013.2A.102-106
Download citation

References

  1. RAO, B.P.C.: Practical eddy current testing. Alpha Science International Ltd.: Oxford, 2007. Go to original source...
  2. JANOUSEK, L., T. MAREK, T., D. GOMBARSKA, D.: Eddy Current Non-destructive Evaluation of Conductive Materials. Communications - Scientific Letters of the University of Zilina, 1, pp. 29-33, 2006. Go to original source...
  3. CHEN, Z., MIYA, K.: A New Approach for Optimal Design of Eddy Current Testing Probes. J. of Nondestructive Evaluation, vol. 17, pp. 105-116, 1998. Go to original source...
  4. STRAPACOVA, T., CAPOVA, K., JANOUSEK, L.: Artificial Heart Valve Inspection Using Eddy Current Techniques. Communications - Scientific Letters of the University of Zilina, vol. 13, No. 2A, pp. 83-86, 2011. Go to original source...
  5. JANOUSEK, L., SMETANA, M.: Uncertainty in Depth Evaluation of Partially Conductive Cracks from Eddy Current Testing Signals. Communications - Scientific Letters of the University of Zilina, vol. 13, No. 2A, pp. 55-60, 2011. Go to original source...
  6. SMETANA, M., STRAPACOVA, T.: Pulsed Eddy Currents as a New Approach in Non-destructive Evaluation of Conductive Materials. Proc. of TRANSCOM 2009, Zilina, pp. 63-66, 2009.
  7. GOMBARSKA, D., SMETANA, M.: Wavelet Based Signal Analysis of Pulsed Eddy Current Signals. Electrical review, vol. 87, pp. 37-39, 2011.
  8. MOTTL, Z.: The Quantitative Relations between True and Standard Depth of Penetration for Air-cored Probe Coils in Eddy Current Testing. NDT International, vol. 23, pp. 11-18, 1990. Go to original source...
  9. ALMAN, M.: Excitation Coil Parameters in View of Eddy Current Distribution in ECT Applications. Proc. of Elektro 2010, Zilina, pp. 221-224, 2010.

This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.